Shift Solenoid Valve O/P Removal and Installation

NOTE:
Keep all foreign particles out of the transmission.


NOTE: Make sure to reset the learned value of CVT system when replacing hydraulically-controlled parts in order not to cause any damage the transmission. The learned value of the CVT system is reset when the negative battery terminal is disconnected.


NOTE: The actual transmission fluid (HCF-2) capacity will vary from the specified capacity based on the length of time the transmission fluid pan is off the transmission. Avoid leaving the transmission fluid pan off for extend periods of time.

4. Shift Solenoid Valve O/P - Remove

1.
Remove the shift solenoid valve O/P (A).

5. All Removed Parts - Install

1.
Install the parts in the reverse order of removal.