CVT Solenoid Valve Test

NOTE:
Keep all foreign particles out of the transmission.
Unless otherwise indicated, illustrations used in the procedure are for 1.5 L engine.

Solenoid Valve Resistance Check

3. Solenoid Valve - Resistance Check

1.
Disconnect the connector (A).

NOTE: To prevent damage, cover the connector using a shop towel.


2.
Measure the resistance between the connector (male terminals) (B) and body ground according to the table.

If the resistance is within the standard, the test is complete, and install all removed parts.
If the resistance is out of the standard, check the solenoid valve operation.

Solenoid valve
Terminal
Standard
Resistance
CVT clutch pressure control solenoid valve
No. 1
4.7?5.9 ?
CVT drive pulley pressure control solenoid valve
No. 8
5.0?6.3 ?
CVT driven pulley pressure control solenoid valve
No. 3
5.0?6.3 ?
CVT lock-up clutch control solenoid valve
No. 4
5.0?6.3 ?
Shift solenoid valve B
No. 5
10.6?13.5 ?
Shift solenoid valve O/P
No. 2
10.6?13.5 ?

CVT Clutch Pressure Control Solenoid Valve

1. CVT Clutch Pressure Control Solenoid Valve - Operation Check



2.
Disconnect the connector (A).

3.
Connect a jumper wire from the positive battery terminal to connector (male terminals) No. 2 (B), and connect another jumper wire from the negative battery terminal to connector terminal No. 1.

If a clicking sound is heard, repair or replace the solenoid wire harness.

2. All Removed Parts - Install

1.
Install the parts in the reverse order of removal.

CVT Drive Pulley Pressure Control Solenoid Valve

1. CVT Drive Pulley Pressure Control Solenoid Valve - Operation Check


1.

NOTE: The actual transmission fluid (HCF-2) capacity will vary from the specified capacity based on the length of time the transmission fluid pan is off the transmission. Avoid leaving the transmission fluid pan off for extend periods of time.


3.
Disconnect the connector (A).

4.
Connect a jumper wire from the positive battery terminal to connector (male terminals) No. 2 (B), and connect another jumper wire from the negative battery terminal to connector terminal No. 1.

If a clicking sound is heard, repair or replace the solenoid wire harness.

2. All Removed Parts - Install

1.
Install the parts in the reverse order of removal.

CVT Driven Pulley Pressure Control Solenoid Valve

1. CVT Driven Pulley Pressure Control Solenoid Valve - Operation Check


1.

NOTE: The actual transmission fluid (HCF-2) capacity will vary from the specified capacity based on the length of time the transmission fluid pan is off the transmission. Avoid leaving the transmission fluid pan off for extend periods of time.


3.
Disconnect the connector (A).

4.
Connect a jumper wire from the positive battery terminal to connector (male terminals) No. 2 (B), and connect another jumper wire from the negative battery terminal to connector terminal No. 1.

If a clicking sound is heard, repair or replace the solenoid wire harness.

2. All Removed Parts - Install

1.
Install the parts in the reverse order of removal.

CVT Lock-Up Clutch Control Solenoid Valve

1. CVT Lock-Up Clutch Control Solenoid Valve - Operation Check



2.
Disconnect the connector (A).

3.
Connect a jumper wire from the positive battery terminal to connector (male terminals) No. 2 (B), and connect another jumper wire from the negative battery terminal to connector terminal No. 1.

If a clicking sound is heard, repair or replace the solenoid wire harness.

2. All Removed Parts - Install

1.
Install the parts in the reverse order of removal.

Shift Solenoid Valve B

1. Shift Solenoid Valve B - Operation Check


1.

NOTE: The actual transmission fluid (HCF-2) capacity will vary from the specified capacity based on the length of time the transmission fluid pan is off the transmission. Avoid leaving the transmission fluid pan off for extend periods of time.

2.
Disconnect the connector (A).

3.
Connect a jumper wire from the positive battery terminal to connector (male terminals) No. 1 (B), and connect another jumper wire from the negative battery terminal to the solenoid valve body.

If a clicking sound is heard, repair or replace the solenoid wire harness.
If no clicking sound is heard, replace shift solenoid valve B.

2. All Removed Parts - Install

1.
Install the parts in the reverse order of removal.

Shift Solenoid Valve O/P

1. Shift Solenoid Valve O/P - Operation Check


1.

NOTE: The actual transmission fluid (HCF-2) capacity will vary from the specified capacity based on the length of time the transmission fluid pan is off the transmission. Avoid leaving the transmission fluid pan off for extend periods of time.

2.
Disconnect the connector (A).

3.
Connect a jumper wire from the positive battery terminal to connector (male terminals) No. 1 (B), and connect another jumper wire from the negative battery terminal to the solenoid valve body.

If a clicking sound is heard, go to the next step.
If no clicking sound is heard, replace the shift solenoid valve O/P.







5.
Connect a tube (B) to the shift solenoid valve O/P.

6.
Blow air into the tube.

If the air goes out of the port (C), go to the next step.
If the air does not go out of the port, replace the shift solenoid valve O/P.

7.
Connect a jumper wire from the positive battery terminal to connector (male terminals) No. 1 (D), and connect another jumper wire from the negative battery terminal to the solenoid valve body.

8.
Blow air into the tube.

If the air goes out of the port, replace the shift solenoid valve O/P.
If the air does not go out of the port, repair or replace the solenoid wire harness.

2. All Removed Parts - Install

1.
Install the parts in the reverse order of removal.